1. Technical Specifications
General Specifications
Charging Mode (IEC 61851-1) | Mode 3 |
Dimensions without cable | 198x201x99 mm (without cable) |
Weight without cable | 1.3 kg (without cable) |
Operating Temperature | -25 ºC to 50 ºC |
Storage Temperature | -40 ºC to 70 ºC |
Environmental Ratings | IP55, IK10 (High resistance) |
Installation location | Indoor and outdoor use |
Mounting Method | Stationary equipment is mounted on the wall. Floor mounting with appropriate Wallbox accessories. |
Intended for use | Equipment intended for use by ordinary persons. |
Location accesses | Equipment for locations with non-restricted access and restricted access |
Product Compliance | RED Directive 2014/53/EU, RoHS Directive 2011/65/EU and BS 7671:2018+A1:2020+A2:2022 Compliant with UK regulations on smart charging |
Electrical Specifications
Charging Power | 7,4 kW (1P) | 11 kW (3P) | 22 kW (3P) |
Rated Voltage AC ± 10% | 230 V | 400 V | 400 V |
Configurable Current | from 6A to rated current |
Rated Frequency | 50 Hz / 60 Hz |
Rated diversity factor (RDF) | 1 |
Residual Current Detection | 6mA DC |
Rated insulation voltage | 400 V |
Rated impulse withstand voltage | 4000 V |
Overvoltage Category | CAT III |
RCCB | Type A, B, or EV might be required according to regional regulations |
Protection against electric shocks | Class I |
Cable Section | Up to 13 mm² |
EV supply equipment connection | AEVCS is permanently connected to the AC mains supply network |
Pollution Degree | PD3 |
Electromagnetic Environment | Class A + Class B |
2. Safety Warnings
- Flying debris, risk of eye injury
- Risk of electric shock. Disconnect and wait 10 mins
- Caution
- Sharp element, risk of injurious cuts
- Ground earth connection required
- Special waste treatment
3. Tools and Mounting Parts
Required tools
- Hammer
- Step drill bit 32mm and bit 8mm
- Pencil
- Flat Screwdriver
- Pillips Screwdriver
- Cutting Pliers
- Torx T20 and T15
- Measuring Tape
- Utility Knife
- Spirit Level
Included mounting parts
- Phillips Screws ø6 x 50 mm
- Phillips Screws ø5 x 40 mm
- Wall Anchors ø8 x 40 mm
- M32 Grommet
- Torx Screws T20 4 x 10 mm
- Torx Screws T15 ø3.5 x 8 mm
4. Preparing the Charger
Remove the two corner screws and carefully lift the cover. Then, carefully detach the ribbon cable to set the cover aside. Before proceeding with the installation, make sure to power off all the connections.5. Installing the Wall Plate
Remove the tape from the wall plate to detach it from the charger. Then, place it straight and mark three holes with a pencil. Now drill with an appropriate-sized bit and place the wall plate in alignment with the holes. If you are mounting your charger on a solid wall, use the wall anchors provided with your charger. Fix the wall plate to the wall, ensuring not to over-tighten the screws. If case power supply wiring comes from the wall, ensure to place the wires through the wall plate hole before fixing the wall plate.6. Lower Connection
Both lower and rear connections are possible when installing Pulsar Max. If you intend to install the product by using the bottom hole, pay attention to the instructions below. For the rear connection, go to section 7. Lift your charger and hang it from the top of the wall plate. Secure the charger to the wall plate with the appropriate screws, avoiding over-tighten. Make an incision on the grommet and insert the power supply cable.7. Rear Connection
Make a hole on the back of the charger, using a Step drill bit 32mm. Then, make an incision in the grommet and insert the power supply cable. Fix your charger to the wall plate and then fix it using the appropriate screws.8. Electrical Wiring
Single Phase Version
- Single Phase Set-up
- Bi-phase No Neutral
- Single Phase PME