

{"id":190923,"date":"2025-01-27T15:39:12","date_gmt":"2025-01-27T14:39:12","guid":{"rendered":"https:\/\/support.wallbox.com\/?post_type=ht_kb&#038;p=190923"},"modified":"2025-04-01T13:07:36","modified_gmt":"2025-04-01T11:07:36","slug":"cosmos-troubleshooting-guide-b-end-user-charger-online","status":"publish","type":"ht_kb","link":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/","title":{"rendered":"Troubleshooting Guide B for Installer Onsite and Charger Offline"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"190923\" class=\"elementor elementor-190923\" data-elementor-post-type=\"ht_kb\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4045eb8 color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4045eb8\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-57319bfd\" data-id=\"57319bfd\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8f619e4 elementor-widget elementor-widget-heading\" data-id=\"8f619e4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Introduction<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ce0fc0a elementor-widget elementor-widget-text-editor\" data-id=\"7ce0fc0a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>This guide is designed for installers to identify the issue on-site and implement the solution quickly. For each symptom you encounter, you&#8217;ll find a series of troubleshooting steps to either identify and fix the problem efficiently or gather the relevant information required when processing a warranty claim. Following the guide can address common issues, such as power failures, connectivity problems, or error codes, ensuring minimal downtime and a successful resolution.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d7c25e1 color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d7c25e1\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d77f9d0\" data-id=\"d77f9d0\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0834e48 elementor-widget elementor-widget-heading\" data-id=\"0834e48\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">1. Issue Identification Table\n<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a1656b elementor-widget elementor-widget-text-editor\" data-id=\"2a1656b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>\u00a0<\/p><table><tbody><tr><td><span style=\"font-weight: 300;\">Symptom<\/span><\/td><td><span style=\"font-weight: 300;\">Root cause<\/span><\/td><td><span style=\"font-weight: 300;\">Supporting documents<\/span><\/td><td><span style=\"font-weight: 300;\">Initial checks<\/span><\/td><\/tr><tr><td><h5><a href=\"#2.1 Symptom: Red Error Status LED Light\u200b\">2.1 Symptom: Red Error Status LED Light\u200b<\/a><\/h5><\/td><td><span style=\"font-weight: 300;\">Known firmware error (shown in Cosmos)<\/span><\/td><td><span style=\"font-weight: 300;\">New error page link<\/span><\/td><td><span style=\"font-weight: 300;\">Identify the firmware error code in Cosmos or the Wallbox App<\/span><\/td><\/tr><tr><td><h5><a href=\"#2.2 Symptom: Dark Blue LED, Charging low current\u200b\">2.2 Symptom: Dark Blue LED, Charging low current\u200b<\/a><\/h5><\/td><td><span style=\"font-weight: 300;\">Installation Issues<\/span><\/td><td><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/installation-guide-ems\/\"><span style=\"font-weight: 300;\">EMS guide<\/span><\/a><\/td><td><p><span style=\"font-weight: 300;\">Check if the car:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Low power mode<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Charge percentage limitations<\/span><\/p><\/td><\/tr><tr><td><h5><a href=\"#2.3 Light Blue LED, &quot;Waiting for green energy&quot;\u200b\">2.3 Light Blue LED, &#8220;Waiting for green energy&#8221;\u200b<\/a><\/h5><\/td><td><p><span style=\"font-weight: 300;\">&#8211; Solar charging issues<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; CP fluctuations<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; WFCD<\/span><\/p><\/td><td><span style=\"font-weight: 300;\">Solar charging info <\/span><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/how-to-activate-and-use-eco-smart\/\"><span style=\"font-weight: 300;\">support website<\/span><\/a><\/td><td><span style=\"font-weight: 300;\">Check there is surplus energy, based on the installation type.<\/span><\/td><\/tr><tr><td><h5><a href=\"#2.4 Symptom: Ready Status, stuck in green LED\u200b\">2.4 Symptom: Ready Status, stuck in green LED\u200b<\/a><\/h5><\/td><td><span style=\"font-weight: 300;\">Lack of continuity\u00a0<\/span><\/td><td><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/pulsar-plus-status-leds-colours-meaning\/\"><span style=\"font-weight: 300;\">Status meanings<\/span><\/a><\/td><td><span style=\"font-weight: 300;\">Check there is no visible damage to the EV Gun.<\/span><\/td><\/tr><tr><td><h5><a href=\"#2.5 Symptoms: No LED light \u200b\">2.5 Symptoms: No LED light<\/a> \u200b<\/h5><\/td><td><span style=\"font-weight: 300;\">Functionalities are affected by a lack of voltage.<\/span><\/td><td><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/pulsar-plus-status-leds-colours-meaning\/\"><span style=\"font-weight: 300;\">Status meanings<\/span><\/a><\/td><td><span style=\"font-weight: 300;\">Ensure the dedicated RCD switch to the charger is in the ON position<\/span><\/td><\/tr><\/tbody><\/table>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-af594ff color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"af594ff\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f01ef8e\" data-id=\"f01ef8e\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9de70a4 elementor-widget elementor-widget-heading\" data-id=\"9de70a4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">2. Step-by-step troubleshooting guides\n<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fd61ce2 elementor-widget elementor-widget-heading\" data-id=\"fd61ce2\" data-element_type=\"widget\" id=\"2.1 Symptom: Red Error Status LED Light\u200b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.1 Symptom: Red Error Status LED Light<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf6cc71 elementor-widget elementor-widget-text-editor\" data-id=\"bf6cc71\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 300;\">Try to put the charger online &#8211; <\/span><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/troubleshooting-for-all-wallbox-chargers\/#wi-fi-troubleshooting\"><span style=\"font-weight: 300;\">Wi-Fi troubleshooting steps<\/span><\/a><span style=\"font-weight: 300;\">.<\/span><\/p><p><span style=\"font-weight: 300;\">If connected, go to <a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-c-end-user-charger-online\/\" target=\"_blank\" rel=\"noopener\">Troubleshooting Guide C<\/a>.<\/span><\/p><p><b>What is the LED 302?<\/b><span style=\"font-weight: 300;\">\u00a0\u00a0<\/span><\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-190927 size-medium alignleft\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-300x255.png\" alt=\"\" width=\"300\" height=\"255\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-300x255.png 300w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-50x43.png 50w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-60x51.png 60w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-100x85.png 100w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1.png 512w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><b><\/b><\/p><ol><li><b>LED301:<\/b> Communication RPi-MCU<\/li><li><b>LED302:<\/b> Error LED. If blinking, count the blinks and record a video for 1 minute.<\/li><li><b>LED303:<\/b><span style=\"font-weight: 300;\"> Heartbeat<\/span><\/li><li><b>Power:<\/b> Power ON<\/li><\/ol><p>\u00a0<\/p><p>\u00a0<\/p><h3><b>How to do a manual restore?<\/b><\/h3><p><b>PULSAR PRO\/PULSAR MAX:<\/b><\/p><p><span style=\"font-weight: 300;\">Press RESTORE and CM RST together, 3 seconds later, release CM RST, and around 10 seconds later release SW201 RESTORE. Keep the RESTORE button pressed until the ATLAS LED turns red.<\/span><\/p><p><img decoding=\"async\" class=\"size-full wp-image-190943 aligncenter\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-3.png\" alt=\"\" width=\"276\" height=\"232\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-3.png 276w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-3-50x42.png 50w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-3-60x50.png 60w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-3-100x84.png 100w\" sizes=\"(max-width: 276px) 100vw, 276px\" \/><\/p><p><b>PULSAR PLUS, COPPER SB &amp; COMMANDER 2\/2s:<\/b><\/p><p><span style=\"font-weight: 300;\">RESTORE: Press SW201(RST) and SW202 together; 3 seconds later, release SW202 and 10 seconds later release SW201.<\/span><\/p><p><img decoding=\"async\" class=\"aligncenter size-full wp-image-190959\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-2.png\" alt=\"\" width=\"269\" height=\"254\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-2.png 269w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-2-50x47.png 50w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-2-60x57.png 60w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-2-100x94.png 100w\" sizes=\"(max-width: 269px) 100vw, 269px\" \/><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb52771 elementor-widget elementor-widget-toggle\" data-id=\"bb52771\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1961\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1961\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause - Firmware errors Mashown on Cosmos<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1961\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1961\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Error code<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Root cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Next steps<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#101<\/b><span style=\"font-weight: 300;\"> &#8211; Leakage Module<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger is not functioning correctly due to a connection or internal error.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1.\u00a0 Disconnect the vehicle and restart the charger.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Once restarted, connect the vehicle.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. If the issue persists, restore the charger.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 1 time<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">A replacement might be required if the error remains in the factory settings.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#102<\/b><span style=\"font-weight: 300;\"> &#8211; Welding<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger has detected that one of its internal relays is stuck in a closed position when it should be open.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Unplug the vehicle<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Power Cycle the charger to the circuit breaker.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a03. Try to charge again.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. Complete the checklist with photos.<\/span><\/p>\n<p><b>LED302 blinks: 2 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error remains, a replacement might be required.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#103<\/b><span style=\"font-weight: 300;\"> &#8211; DC Leakage<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger has detected a direct current (DC) leak, which could originate from the vehicle\u2019s onboard charger (OBC), the charger itself, or the electrical installation.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Unplug the vehicle and restart the charger.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Measure the input connector between Neutral and Earth (DC). If the voltage is higher than 5V &gt; contact the electricity supplier to report it.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. If less than 5V, conduct a test with an EV tester and make a video.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Please complete the checklist with photos.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. Complete the checklist with photos.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><b>LED302 blinks: 3 times<\/b><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><i><span style=\"font-weight: 300;\">If the test with the tester does not cause the error, then the vehicle or the socket on the customer&#8217;s vehicle is the cause of the leak, and the charger must not be replaced.<\/span><\/i><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error remains, a replacement might be required.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#104<\/b><span style=\"font-weight: 300;\"> &#8211; CP to GND<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger has detected an issue with the control pilot (vehicle communication) circuit.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Switch off the charger and unplug the charger from the car.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Check the connection of the EV gun control pilot to the charger and try again<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. If less than 5V, conduct a test with an EV tester and make a video.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">4. Complete the checklist with photos.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><b>LED302 blinks: 4 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error remains, a replacement might be required.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#106<\/b><span style=\"font-weight: 300;\"> &#8211; CP Undefined state<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">Status: Red or Multicolored Statuses (change to Blue\/Red\/Green\/Turquoise)<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger has detected an unexpected voltage on the control pilot (CP) signal, which does not align with the standard ranges.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Disconnect the vehicle.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. If the error appears when it is not connected, restore the charger on the app or manually restore it.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. Take a photo of the charger&#8217;s supply voltage measurement between Phase 1 and Neutral, showing a correct voltage (230V) &gt; then restart the charger at the circuit breaker.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><b>LED302 blinks: 6 times<\/b><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><i><span style=\"font-weight: 300;\">If the error only appears when a vehicle is connected, please make a video of the test with your EV tester.<\/span><\/i><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">A replacement might be required if the error remains in the factory settings.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><i><span style=\"font-weight: 300;\">Rare cases: The issue can happen only when the car is connected, which can be due to car resistance.<\/span><\/i><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#107<\/b><span style=\"font-weight: 300;\"> &#8211; Socket locking error &#8211; COPPER SB &amp; PULSAR PLUS SOCKET<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger could not lock the EV gun properly, which could be due to incorrect insertion.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Connect the cable to the vehicle (not to the charger)<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Connect the cable to it. (please force the cable into the charger).<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">The LED should turn red.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. Try a power cycle or restart from the app (After doing a power cycle, there is a 30-second window where you can release the EV gun after it is locked again).<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">4. If the hose is blocked, follow the steps below:<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; Push the cable further inside the socket.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; After the charge session, &#8211; Disconnect the hose from the car.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Make sure to unlock the charger from the app. (green color)<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Remove the hose from the charger<\/span><\/p>\n<p><span style=\"font-weight: 300;\">5. Repeat all steps one more time.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 7 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Recoverable, most cases are due to the customer misconnecting the cable.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">A replacement might be required if the error remains in the factory settings.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#109 &#8211;<\/b><span style=\"font-weight: 300;\"> Protective Earth <\/span><span style=\"font-weight: 300;\">(UK CHARGERS ONLY)<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger has detected that the voltage between L1 and N is outside the acceptable limits defined by UK regulations, preventing it from operating.\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Check the voltage between L1 &#8211; N<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 9 times<\/b><\/p>\n<br \/>\n<p><i><span style=\"font-weight: 300;\">If the voltage returns to the correct value for a stable time window (2 minutes), the error is automatically erased, and the charger usually works without user interaction.<\/span><\/i><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">&#8211; If it is greater than 254 V or lower than 210 V, contact the electrical provider.\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; A replacement might be required if it is lower than 254 V and greater than 210 V.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.\u00a0<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#110 &#8211;<\/b><span style=\"font-weight: 300;\"> Proximity<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger can not correctly read the charging cable resistor.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Make a video: Remove the cable. The terminal turns white again, reconnect the cable once again, and the terminal returns to error.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Pre-open the terminal, insert the cable, and video the 302 LED flashing 10 times.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. If the error appears when it is not connected, restore the charger on the app or manually restore it.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">4. Complete the checklist with photos.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 10 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Auto-recoverable\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">PULSAR PLUS SOCKET or COPPER SB: Try another EV Gun. If another EV Gun works, suggest that the customer replace its cable.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">PULSAR MAX. PULSAR PRO and COMMANDER 2\/2s: Measure the resistance between the proximity driver and the earth protection on the EV Gun with the charger switched off. <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">A replacement might be required if the value is not close to 220 Ohm.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#111 &#8211;<\/b><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Ground Monitor<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger detects a too-high resistance or voltage between L1 and N. The charger senses that the protective earth has been disconnected.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Ensure that the protective earth is connected to the input and output of the charger.\u00a0<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 11 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">&#8211; Check the voltage between the protective earth and N. Contact the electrical provider if it is too high (more than 10 V).<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; If it is low, the ground monitor of the charger has been broken.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">A replacement might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#112 &#8211;<\/b><span style=\"font-weight: 300;\"> Undervoltage<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger measured a voltage between L1 and N lower than 150V, below the acceptable threshold.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Measured voltage between L1 and N is lower than 150V.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Do a manual restore of the charger.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. Power cycle the charger.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. Remove the Molex cable and clean the pins carefully.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">5. Complete the Checklist with photos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">6. Then, make a video in which you take the voltage on the charger&#8217;s power supply terminal block between L1 and N for at least 15 seconds so that we can see that there is no voltage drop.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 12 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error still remains in the factory settings, a replacement might be required.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#113 &#8211;<\/b><b><br \/><\/b><span style=\"font-weight: 300;\">Control Pilot High Undefined<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The voltage of the control pilot during the high-level period has an unexpected value.\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">N\/A<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 13 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#114 &#8211; <\/b><b><br \/><\/b><span style=\"font-weight: 300;\">Control Pilot High Undefined<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The voltage of the control pilot during the low-level period has an<\/span><\/p>\n<p><span style=\"font-weight: 300;\">unexpected value<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist with photos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Remove the EV gun and check whether the Halo\/LED turns green.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 14 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Recoverable.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">A replacement might be required if the error remains in the factory settings.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#115 &#8211;\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Control Pilot High to GND<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The voltage of the control pilot during the low-level period has an<\/span><\/p>\n<p><span style=\"font-weight: 300;\">unexpected value.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist with photos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Remove the EV gun and check whether the Halo\/LED turns green.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 15 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error still remains in the factory settings, a replacement might be required.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#116 &#8211;\u00a0\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Static Load Management, multiple primaries<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The user has configured more than one charger in the network.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Using in the App or Portal, remove the Static Load Management configuration of all the chargers configured except one.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Restore all chargers configured as masters.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0\u00a0<\/span><\/p>\n<p><b>LED302 blinks: 16 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Auto-recoverable<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#117 &#8211;<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Static Load Management not configured<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No primary yet; this is the initial installation stage. After boot-up, the primary configuration isn&#8217;t set.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist with photos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Along with close-up photos of:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Current selector switch position.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; CAN switch the position of each serial number, which must be easily visible to avoid doubts.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; Photos of the CAN block connector for each charger in the installation, in the order in which they were installed.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; Measure the resistance (power off) between each CAN L and CAN H on the connector blocks of each charger to check that none has an internal fault.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 17 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Provide these pictures as a replacement might be required.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#118 &#8211;<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Static Load Management<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Slave Unpaired<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The total number of chargers exceeds the Static Load Management configuration.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist with photos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Along with close-up photos of:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Current selector switch position.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; CAN switch position of each SN &#8211; the position must be readily visible to avoid doubts.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; Photos of the CAN block connector for each charger in the installation, in the order in which they were installed.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; Measure the resistance (power off), between each CAN L and CAN H on the connector blocks of each charger to check that none has an internal fault.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 18 times<\/b><span style=\"font-weight: 300;\">\u00a0\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Provide these pictures as a replacement might be required.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#119 &#8211;\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">CCID Tripped<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">There is a current leak in the load (OBC) or the charger itself. It could also happen due to the installation.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Complete the checklist and photos.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 19 times<\/b><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error is fixed, connect the EV gun. <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error is triggered again, contact the car company.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error still remains after, a replacement might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#120 &#8211;\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">CCID Prompt Tripped<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">There is a current leak in the load (OBC) or the charger itself. It could also happen due to the installation.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">2. Complete the checklist and photos.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 20 times<\/b><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<br \/><br \/><\/td>\n<td>\n<p><span style=\"font-weight: 300;\"> If the error is fixed, connect the EV gun. <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error is triggered again, contact the car company.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error still remains after, a replacement might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#121 &#8211;\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">CCID Self Test<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The leakage sensor is not working correctly.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Unplug the EV gun.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Power Cycle the charger for 1 minute.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. Complete the checklist and photos.<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 21 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error still remains in the factory settings, a replacement might be required.<\/span><\/p>\n<p><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><b>#123 &#8211;<\/b><\/p>\n<p><span style=\"font-weight: 300;\">AC Leakage<\/span><\/p>\n<br \/><br \/><\/td>\n<td>\n<p><span style=\"font-weight: 300;\">There is an AC current leak, either in the load (OBC) or in the charger itself. It could also happen due to the installation.<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check the voltage (in AC) between the protective earth and neutral.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. If the voltage is high (tens of V), contact the electrical provider.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. If the voltage is low, then unplug the EV gun and proceed to the solutions.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><b>LED302 blinks: 23 times<\/b><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If the error is fixed, connect the EV gun.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error is triggered again, contact the car company.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">If the error still remains in the factory settings, a replacement might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br \/><br \/><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-52825bb color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"52825bb\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-131c072\" data-id=\"131c072\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-67cc39a elementor-widget elementor-widget-heading\" data-id=\"67cc39a\" data-element_type=\"widget\" id=\"2.2 Symptom: Dark Blue LED, Charging low current\u200b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.2 Symptom: Dark Blue LED, Charging low current<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2269e83 elementor-widget elementor-widget-text-editor\" data-id=\"2269e83\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span> <b>Check the settings on the car side<\/b><\/p>\n<p><i><span style=\"font-weight: 300;\">&#8211; Low Power Mode<\/span><\/i><span style=\"font-weight: 300;\"> refers to a setting that limits the amount of power the vehicle draws from the charger during the charging process.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; <\/span><i><span style=\"font-weight: 300;\">Charge percentage limitations<\/span><\/i><\/p>\n<p><span style=\"font-weight: 300;\">The charger percentage limitation setting for electric vehicles (EVs) refers to a feature that allows drivers to set a limit on how much of the battery&#8217;s total capacity the car will charge to. The setting will reduce the charging rate when it is almost at the charge percentage limit.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 2:<\/span> <b>Follow the Energy Management Solutions installation guide<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Ensure that during the initial installation of the EMS feature, the installer followed the manual carefully, paying particular attention to each feature, charger, and accessory as specified.<\/span><\/p>\n<p><b>Step 3:<\/b> <b>Check the settings on the Wallbox app.<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Ensure that the power limit setting on the app is set to the desired limit. This setting can be lowered by default when the app is updated.\u00a0<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger chargers max up to 6A for phase.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Wrong Installation:<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">There is no connection between the chargers, and it can be due to the wrong installation set up or the resistances in the socket not working properly. Please see the specific steps per metre below.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-84cc255 elementor-widget elementor-widget-toggle\" data-id=\"84cc255\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1391\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1391\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - Static Load Management = Installation issues<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1391\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1391\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Connect to the primary charger via Bluetooth then try to configure again, <\/span><span style=\"font-weight: 300;\"><br \/><br \/><\/span><\/p>\n<p><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/troubleshooting-for-all-wallbox-chargers\/\"><span style=\"font-weight: 300;\">Bluetooth Troubleshooting Guide<\/span><\/a><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">Follow the EMS guide for the set-up of the current selector and the switches, depending on the charger models.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Gather some information:\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">PULSAR PRO\/MAX: Measure the resistance between D+ and D- should be 60 \u03a9 with all the cables connected, if it\u2019s not try to change the position of the PRWBST switch and try to configure it again.\u00a0 <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">PULSAR PLUS, COPPER SB &amp; COMMANDER 2\/2s: Measure the resistance between Can L and Can H should be 60 \u03a9 with all the cables connected, if it\u2019s not try to change the position of the CANBUS switch and try to configure it again.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1392\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1392\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #2 - Dynamic Load Management = Installation issues<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1392\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1392\"><p><strong>Carlo Gavazzi meter issues: EM112\/EM330 &amp; EM340<\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Take pictures of installation\/ meter<\/span><\/p><p><span style=\"font-weight: 300;\">2. Ensure an STP cat 5e cable<\/span><\/p><p><span style=\"font-weight: 300;\">3. PWSR switch on \/ Legacy chargers RS485 on T<\/span><\/p><p><span style=\"font-weight: 300;\">4. Check ADDRESS on the Dynamic Load Management meter: should be 001.<\/span><\/p><p><span style=\"font-weight: 300;\">5. Disconnect Wallbox \/ restore the charger on the app.<\/span><\/p><p><span style=\"font-weight: 300;\">6. Ensure RxTx is visible on meter (communication is established)<\/span><\/p><p><span style=\"font-weight: 300;\">Yes? via bluetooth connection PB activated in Wallbox App.<\/span><\/p><p><span style=\"font-weight: 300;\">No? Measure resistance:<\/span><\/p><p><span style=\"font-weight: 300;\">7. Multimeter needed; Resistance Measurements:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the power is completely off before measuring.<\/span><\/p><p><span style=\"font-weight: 300;\">Measure resistance between D+ and D- on the energy meter side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the Wallbox side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on both the Wallbox and energy meter sides without the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 120 Ohms (on both sides).<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><strong>N1CT<\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Ensure there is no damage to the charger internally or externally.<\/span><\/p><p><span style=\"font-weight: 300;\">2. Confirm that the STP cat 5e cable was used.<\/span><\/p><p><span style=\"font-weight: 300;\">3. Confirm that the meter is receiving power &#8211; you should see a red LED in the meter confirming it is receiving power from the charger.<\/span><\/p><p><span style=\"font-weight: 300;\">4. Confirm the resistor is installed on the N1CT.<\/span><\/p><p>5. Confirm the STP cable wiring- check the cables&#8217; positioning with the EMS Guide.<\/p><p><span style=\"font-weight: 300;\">6. Confirm cables are untwisted and only one wire per input hole.\u00a0<\/span><\/p><p><span style=\"font-weight: 300;\">7. Ensure no copper is visible.<\/span><\/p><p><span style=\"font-weight: 300;\">8. Ensure the RS485(PWR BST) is on T.<\/span><\/p><p><span style=\"font-weight: 300;\">9. Multimeter needed; Resistance Measurements:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the power is completely off before measuring.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the energy meter side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the Wallbox side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on both the wallbox and energy meter sides without the STP cable being connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 120 Ohms (on both sides).\u00a0\u00a0<\/span><\/p><p>Confirm the clamp is reading energy correctly; the arrow inside the clamp should be reading from the grid, as indicated by L in the clamp, to the home, as indicated by K.<\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><strong>P1 Port<\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Refer to TS of:\u00a0 EM112\/EM340 and EM330<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">2. Difference:<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the smart meter is newer than 2015\/2016.<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">&#8211; The top light is a power light. If it is off, check if the meter is working correctly.\u00a0<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Check if the RS485 LED is off.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Check STP cabling with the EMS Guides.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Bottom light off &#8211; Check smart meter connection.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><strong>Tempco Clamp<br \/><\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Check if Dynamic Load Management is enabled on the app.<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">2. Check what the app is displaying.<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">3. Ask the customer for a picture of the meter and the clamp installation<\/span><\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">4. Ask for a picture of the meter when the car is not charging; when it is, check to see if the meter can see the charging happening.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Ensure there is no damage to the charger internally or externally.<\/span><\/p><p><span style=\"font-weight: 300;\">2. Confirm that the STP cat 5E cable was used.<\/span><\/p><p><span style=\"font-weight: 300;\">3. Confirm that the meter is receiving power &#8211; you should be able to see a red LED lit up in the meter confirming it is receiving power from the charger.<\/span><\/p><p><span style=\"font-weight: 300;\">4. Confirm the resistor is installed on the N1CT.<\/span><\/p><p>5. Confirm the STP cable&#8217;s correct wiring- check the wires&#8217; positioning with the EMS Guide.<\/p><p><span style=\"font-weight: 300;\">6. Confirm cables are untwisted and only one wire per input hole.\u00a0<\/span><\/p><p><span style=\"font-weight: 300;\">7. Ensure no copper is visible.<\/span><\/p><p><span style=\"font-weight: 300;\">8. Ensure the RS485(PWR BST) is on T.<\/span><\/p><p><span style=\"font-weight: 300;\">9. Multimeter needed; Resistance Measurements:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the power is completely off before measuring.<\/span><\/p><p><span style=\"font-weight: 300;\">Measure resistance between D+ and D- on the energy meter side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the Wallbox side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on both the Wallbox and energy meter sides without the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 120 Ohms (on both sides).\u00a0\u00a0<\/span><\/p><p>\u00a0<\/p><p>Confirm the clamp is reading energy the correct way; the arrow inside the clamp should be reading from the grid, as indicated by L in the clamp, to the home, as indicated by K in the clamp.<\/p><p>\u00a0<\/p><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><strong>Pro 380 mod<br \/><\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">Symptom<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">The charger chargers max up to 6A for phase.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">Cause<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">Wrong installation or not proper resistance:<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">There is no connection between the chargers, and it can be due to the wrong installation set up or the resistances in the socket not working properly.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Take pictures of installation\/ meter<\/span><\/p><p><span style=\"font-weight: 300;\">2. Ensure an STP cat 5e cable<\/span><\/p><p><span style=\"font-weight: 300;\">3. PWSR switch on \/ Legacy chargers RS485 on T<\/span><\/p><p>4. Check the ADDRESS on the Dynamic Load Management meter: it should be 001.<\/p><p><span style=\"font-weight: 300;\">5. Disconnect the Wallbox \/ restore the charger on the app.<\/span><\/p><p><span style=\"font-weight: 300;\">6. Ensure RxTx is visible on the meter (communication is established)<\/span><\/p><p><span style=\"font-weight: 300;\">Yes? via Bluetooth connection, PB activated in Wallbox App.<\/span><\/p><p><span style=\"font-weight: 300;\">No? Measure resistance:<\/span><\/p><p><span style=\"font-weight: 300;\">7. Multimeter needed; Resistance Measurements:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the power is completely off before measuring.<\/span><\/p><p><span style=\"font-weight: 300;\">Measure resistance between D+ and D- on the energy meter side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the Wallbox side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on both the Wallbox and energy meter sides without the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 120 Ohms (on both sides).<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><strong>Inempro Pro mod 2<br \/><\/strong><\/p><table><tbody><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Take pictures of installation\/ meter<\/span><\/p><p><span style=\"font-weight: 300;\">2. Ensure an STP cat 5e cable<\/span><\/p><p><span style=\"font-weight: 300;\">3. PWSR switch on \/ Legacy chargers RS485 on T<\/span><\/p><p>4. Check the ADDRESS on the Dynamic Load Management meter: it should be 001.<\/p><p><span style=\"font-weight: 300;\">5. Disconnect the Wallbox \/ restore the charger on the app.<\/span><\/p><p><span style=\"font-weight: 300;\">6. Ensure RxTx is visible on a meter (communication is established)<\/span><\/p><p><span style=\"font-weight: 300;\">Yes? Via Bluetooth connection, PB activated in Wallbox App.<\/span><\/p><p><span style=\"font-weight: 300;\">No? Measure resistance:<\/span><\/p><p><span style=\"font-weight: 300;\">7. Multimeter needed; Resistance Measurements:<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Ensure the power is completely off before measuring.<\/span><\/p><p><span style=\"font-weight: 300;\">Measure resistance between D+ and D- on the energy meter side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on the Wallbox side with the STP cable connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 60 Ohms.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Measure resistance between D+ and D- on both the wallbox and energy meter sides without the STP cable being connected.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Expected Resistance: 120 Ohms (on both sides).<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">A replacement charger or meter might be required.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the Webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2a87d7 elementor-widget elementor-widget-heading\" data-id=\"c2a87d7\" data-element_type=\"widget\" id=\"2.3 Light Blue LED, &quot;Waiting for green energy&quot;\u200b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.3 Light Blue LED, \"Waiting for green energy\"<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e125aa elementor-widget elementor-widget-text-editor\" data-id=\"2e125aa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span> <b>Follow the Energy Management Solutions installation manual<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Ensure that during the initial installation of the EMS feature, the installer followed the manual carefully, paying particular attention to each feature, charger, and accessory as specified.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 2:<\/span> <b>Ensure there is enough surplus for the installation<\/b><\/p>\n<p><i><span style=\"font-weight: 300;\"><strong>Eco-mode:<\/strong> Combines the energy from the grid with the surplus of green energy.<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 300;\">Surplus &gt;= 2A =<\/span><\/i> <i><span style=\"font-weight: 300;\">&#8211; 0,46kWh\u00a0 in 1-phase<\/span><\/i> <i><span style=\"font-weight: 300;\">-1,38kWh 3-phases<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 300;\"><strong>Full-Green:<\/strong> uses only the surplus of green energy to charge.<\/span><\/i><\/p>\n<p><i><span style=\"font-weight: 300;\">Surplus &gt;= 6A =<\/span><\/i> <i><span style=\"font-weight: 300;\">-1,38kWh in 1-phase<\/span><\/i> <i><span style=\"font-weight: 300;\">-4,140kWh in 3-phases<\/span><\/i><\/p>\n<p><b>Step 3:<\/b> <b>Factors to consider.<\/b><\/p>\n<p><span style=\"font-weight: 300;\">Necessary: Correct installation of the Dynamic Load Management (single charger). If this feature does not work, refer to the Dynamic Load Management troubleshooting per meter in this guide.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Not compatible with Static Load Management and Dynamic Load Management (multiple chargers) at the moment.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Can discharge the home batteries in the installation.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Schedule charging sessions on the app or manual charges (pressing play in the app) will override the Solar Charging features.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Not available for Renault ZE-ready vehicles.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b9b7ae7 color-black elementor-widget elementor-widget-toggle\" data-id=\"b9b7ae7\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1941\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1941\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - Solar Charging Installation issue<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1941\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1941\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger chargers max up to 6A for phase.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Wiring meter &#8211; charger incorrect.\u00a0<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">2. Defective meter.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">3. Channel RS485 defective.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">4. Incorrect position of the meter.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">5. Not enough green energy.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check the instructions for wiring the specific meter with the charger and check the continuity of the STP cable, also check if the cable is a STP cat 5e or higher as the manual request.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">2. If the meter has a screen and this one is off with the inputs connected, the meter has to be replaced. In the case of N1CT, the red light on the side has to be on; otherwise, the meter is defective. Check resistance in meter D-, D+ without wiring; it has to be 120 ohms; otherwise, the meter is also faulty.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">3. Check if the RS485 channel is defective measuring D-,D+. Has to be 120 ohms without STP cable, in some cases we see an open loop OL, this also confirms that the channel RS485 is defective and the unit has to be replaced.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">4. If the meter located in the charger&#8217;s fuse box will measure the charger&#8217;s consumption, the meter needs to be placed before the solar meter to read the surplus in the place.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Try the charger as a stand-alone, and turn off the Solar Charging feature.<br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1942\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1942\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #2 - Waiting for Car Demand and CP Fluctuations<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1942\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1942\"><p><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span> <b>Check the settings on the car side<\/b><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; <\/span><i><span style=\"font-weight: 300;\">Charge percentage limitations<\/span><\/i><\/p>\n<p><span style=\"font-weight: 300;\">The charger percentage limitation setting for electric vehicles (EVs) refers to a feature that allows drivers to limit how much of the battery&#8217;s total capacity the car will charge.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">The charging session could stop early if the customer is unaware that this setting is being enabled. Once a session stops and the charger is plugged into the car, the charger&#8217;s status is \u2018Waiting for Car Demand\u2019.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; <\/span><i><span style=\"font-weight: 300;\">Ensure there are no conflicting schedules set on the car side<\/span><\/i><\/p>\n<p><span style=\"font-weight: 300;\">When a customer sets a charging session schedule on the Wallbox and car apps, this can cause the WFCD status. Ensure they are only using one of the apps only.\u00a0<\/span><\/p>\n<p>\u00a0<\/p>\n<p><span style=\"font-weight: 900;\">Step 2:<\/span> <i><span style=\"font-weight: 300;\">Does the customer have access to another vehicle to try and charge?<\/span><\/i> <b>\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 300;\">This will determine if the issue comes from a setting within the car.\u00a0<\/span><\/p>\n<p><strong>WFCD &#8211; CP FLUCTUATIONS\u00a0\u00a0<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Dark Blue status and after a few seconds goes to light blue status<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Faulty Molex cable: <\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Due to flat cable the CP voltage is fluctuating and this is affecting the behavior of the charger.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span>The flat pin cable may be damaged, not correctly connected to the carrier board, or on the high voltage board, or the pins may not be pressed adequately by the connector. Therefore the CP voltage is fluctuating, affecting the charger&#8217;s behaviour.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check the voltage of the charger, and measure L1-N in the input in VAC. Record a video of the readings for 1 minute.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Take a picture of the CP-PE reading in VDC.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Check if the flat pin cable (Molex) is not connected correctly, and clean the connector&#8217;s pins with a proper contact cleaner.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">The Molex cable might need to be replaced. Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the <a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\" target=\"_blank\" rel=\"noopener\">contact form<\/a>\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br \/><br \/><br \/><br \/><br \/><\/p>\n<p><span style=\"font-weight: 300;\">(3.2.3) <\/span><span style=\"font-weight: 300;\">WFCD &#8211; Other Issues\u00a0<\/span><\/p>\n<p><br \/><br \/><\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Light Blue status<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Option 1: The real voltage fluctuations make the charger change between status\u2019. As a result some cars do not accept the charge, leaving the charger in \u2018Waiting For Car Demand\u2019 status (some cars report charging errors on their screens).<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Option 2: Sometimes the flat cables are ok but the PWM signal is not being assigned correctly to the EV and the EV is waiting until this signal is assigned.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. The electrical installation must be both NEUTRAL and EARTHED. Without this Neutral and Earth connection the car will not charge. It will not work in a two\/three phase 230V system without these connections.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. The difference between neutral and ground must be LESS than 5V. Otherwise the installation has a bypass or broken devices that cause \u201cunbalanced loads\u201d. It would then be necessary to check pumps, refrigerators and other electrical equipment &#8230; In case of outside the home installation it would be necessary to contact the electricity company.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">In the ideal situation, this voltage is as close to Zero as possible.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. Earth resistance must be less than 150 Ohm. The installation should be checked.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. It is important that the electric noise\/interference level does not exceed 4%. The \u201charmonic distortion\u201d must comply with UNE 61000-2-1 standard laws. (Installer companies can check this and install filters)<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; We have seen cases where the problem is solved by:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0\u00a0\u00a0&#8211; A software update on the car<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0\u00a0\u00a0&#8211; By making sure the EV gun cable is straight and not coiled or wrapped around<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4.- Discuss with L2 in order to check the provider of the EV cable.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check if the flat Molex cable is properly connected and clean the pins of the connector with a proper contact cleaner.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Check if the input voltages fluctuate frequently, measure L1-N to confirm and check this against the AC Voltage readings in Cosmos.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. If possible, try with another electric vehicle to check if the issue is still present in both or try with an EV tester to check if the charger is able to change between states properly.\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">&#8211; We have seen cases where the problem is solved by:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0\u00a0\u00a0&#8211; A software update on the car<\/span><\/p>\n<p><span style=\"font-weight: 300;\">\u00a0\u00a0\u00a0&#8211; By making sure the EV gun cable is straight and not coiled or wrapped around<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Open a case and discuss with L2 in order to check the provider of the EV cable.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br \/><br \/><br \/><br \/><br \/><br \/><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-619bbbf color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"619bbbf\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-304963f\" data-id=\"304963f\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d744916 elementor-widget elementor-widget-heading\" data-id=\"d744916\" data-element_type=\"widget\" id=\"2.4 Symptom: Ready Status, stuck in green LED\u200b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.4 Symptom: Ready Status, stuck in green LED<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3bb661 elementor-widget elementor-widget-text-editor\" data-id=\"b3bb661\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span><span style=\"font-weight: 300;\"> Check for any damage to the EV gun<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Check the EV gun cable and connector for any damage caused by misuse or mishandling. For example, a disconnection from the charger, a warped cable or visible damage to the EV gun\/cable.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 2: <\/span><span style=\"font-weight: 300;\">Ensure there are no adapters\/extenders on the EV gun cable<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; The use of adapters on the EV gun can cause this issue. External companies can purchase adapters to change the EV gun from type 2 to type 1 and vice versa.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; It is also possible to purchase extension cables from external companies.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Wallbox cannot recommend using adapters and extenders as this can affect the charger. *Changing the cable will also void the warranty.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ba6994 color-black elementor-widget elementor-widget-toggle\" data-id=\"0ba6994\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1221\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1221\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - Lack of Continuity in CP Cables<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1221\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1221\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Stuck in the Ready status<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Once the EV gun is connected to the car, the Wallbox stays in a green status:<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">The signal of the Control Pilot cannot reach the charger because the cable has no continuity.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Physically check the condition of the cable and look for signs of strain.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">2. Move the cable to see if there is any loss of continuity at any point. Measure continuity on the CP cable.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">3. Check for signals of pulled EVG\/manipulation (NOTE: if a lousy manipulation sign is detected in the charger, it will result in an out of warranty)<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. CP-PE measurement inside the charger (in VDC)<\/span><\/p>\n<p><span style=\"font-weight: 300;\">5. CP-PE measurement on the EV cable (in VDC)<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">The values can be measured in two ways:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">1. Inserting the multimeter probes into the ground + the reference point of the CP.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Measuring with the multimeter at two cooling points of the CP.\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; You need to open the three screws carefully.\u00a0<\/span><\/p>\n<p>&#8211; Ensure all outgoing cables to the charger are appropriately connected, and the CP (white) cable is connected correctly.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">If signals of pulled EVG\/manipulation &gt; WC NO<\/span><\/p>\n<p><span style=\"font-weight: 300;\">If there are no signs of pulled EVG\/manipulation &gt; <\/span><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> or use the Partner Portal&#8217;s contact form.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br \/><br \/><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6007d74 color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6007d74\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a6ed266\" data-id=\"a6ed266\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1b8ddfc elementor-widget elementor-widget-heading\" data-id=\"1b8ddfc\" data-element_type=\"widget\" id=\"2.5 Symptoms: No LED light \u200b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.5 Symptoms: No LED light <\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-246fa5b elementor-widget elementor-widget-text-editor\" data-id=\"246fa5b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 300;\">\u00a0<\/span><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span><span style=\"font-weight: 300;\"> Ensure the RCD switch is in the \u2018ON\u2019 position<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 2: <\/span><span style=\"font-weight: 300;\">Check the \u2018Halo Standby\u2019 feature on the app is not enabled.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Go to the settings on the app &gt; Connect to the Bluetooth &gt; If it is enabled, slide the dial to disable that feature &gt; Press save.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8ca30c2 elementor-widget elementor-widget-toggle\" data-id=\"8ca30c2\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1471\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1471\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - No LED light<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1471\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1471\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Halo\/LED off &#8211; Unresponsive<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Once the EV gun is connected to the car, the Wallbox is unresponsive:<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">The voltage that arrives at the carrier (output side of the PSU) is lower than 12V. Therefore, the functionalities are affected by a lack of voltage.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check if the RCDs are property activated.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. If the varistors burn it, WC NO as the burn happens due to High voltage from the greed.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. If the varistors are ok, inputs well-connected request pictures measuring phase-neutral. If we have a proper value of 230, then the Issue will confirm it, and the unit needs to be replaced under warranty.\u00a0\u00a0<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">4. Here are example pictures to provide on the case:\u00a0<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-190991 size-medium\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-225x300.jpg\" alt=\"Cosmos Troubleshooting guide - Image 4\" width=\"225\" height=\"300\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-225x300.jpg 225w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-38x50.jpg 38w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-45x60.jpg 45w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-75x100.jpg 75w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed.jpg 768w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-190975 size-medium\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-225x300.jpg\" alt=\"Cosmos Troubleshooting guide - Image 5\" width=\"225\" height=\"300\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-225x300.jpg 225w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-768x1024.jpg 768w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-38x50.jpg 38w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-1152x1536.jpg 1152w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-45x60.jpg 45w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1-75x100.jpg 75w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/unnamed-1.jpg 1200w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Measure voltage between CP-PE (PSU values should be between 11.8V-12V)\u00a0\u00a0<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">In some cases you can see the light of power still on but the rest of the leds in the cover are off, this is also under warranty if the varistors are ok and no damage caused by the customer. Collect internal pictures of the charger and please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0f351dd color-black elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0f351dd\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-43d91b7\" data-id=\"43d91b7\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a9335b2 elementor-widget elementor-widget-heading\" data-id=\"a9335b2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.6 Symptom: Charging Sessions Errors<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a5acb6c elementor-widget elementor-widget-toggle\" data-id=\"a5acb6c\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1731\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1731\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - 0 KW sessions  <\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-1731\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1731\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Red Status or 0kw sessions reported on Cosmos<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The Wallbox stays in error without the car connected or after the charge,e there are zero value in the kW session:<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">When the Wallbox is connected, it reports over-voltage up to +500V. Fake current readings when nothing is connected (or when 0 kW session value during and after the charge)<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Measure L1-N in vAC.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Check if the flat pin cable (Molex) is misconnected. It can then be solved by reconnecting the flat cable as it should be.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">A Molex cable might need to be replaced. Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a00b10 elementor-widget elementor-widget-heading\" data-id=\"1a00b10\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">2.7 Symptoms: Connectivity issues<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-834cc0c elementor-widget elementor-widget-text-editor\" data-id=\"834cc0c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><span style=\"font-weight: 900;\">Before you start:<\/span><\/p>\n<p><span style=\"font-weight: 900;\">Step 1:<\/span><\/p>\n<p><span style=\"font-weight: 300;\"> Ensure <\/span><a href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/troubleshooting-for-all-wallbox-chargers\/\"><span style=\"font-weight: 300;\">basic troubleshooting<\/span><\/a><span style=\"font-weight: 300;\"> has been done for each connectivity issue.<\/span><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c6224d elementor-widget elementor-widget-toggle\" data-id=\"2c6224d\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-4651\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-4651\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #1 - Bluetooth Connection Fails<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-4651\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-4651\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Bluetooth Connection failed<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">&#8211; Connection failure \u2013 The devices cannot connect, even after several attempts.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Unstable connection \u2013 The connection between the devices frequently drops or experiences interruptions.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Failure to detect \u2013 The Bluetooth device does not appear in the list of available devices.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Ensure all basic troubleshooting has been done from the previous &#8211; take screenshots or pictures of any failed steps.<\/span><\/p>\n<p><b>Try to connect after every step.<\/b><span style=\"font-weight: 300;\">\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Forget the known BT device WBXXXXXX and close the app.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. Perform a power cycle.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. Download a Bluetooth scanning app called BLE Scanner 4.0 (the <\/span><a href=\"https:\/\/apps.apple.com\/us\/app\/ble-scanner-4-0\/id1221763603\"><span style=\"font-weight: 300;\">Apple<\/span><\/a><span style=\"font-weight: 300;\"> and <\/span><a href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.macdom.ble.blescanner&amp;hl=en\"><span style=\"font-weight: 300;\">Android<\/span><\/a><span style=\"font-weight: 300;\"> versions here). Attach screenshots and pictures from the app showing the error.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">5. Open the cover and record a video of the internal LED indicators 301\/302\/303.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">6. Manual restore<\/span><\/p>\n<p><span style=\"font-weight: 300;\">7. Uninstall and reinstall the app.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Try with another device.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Check if the Molex (flat grey) cable is connected correctly and has no damage.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Turn off the charger, remove, and reinsert the Raspberry Pi (ONLY PULSAR PLUS, COPPER SB &amp; COMMANDER 2\/2s)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">A new charger\/cover is needed. Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-4652\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-4652\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #2 - Ethernet connectivity<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-4652\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-4652\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Unable to connect the charger to the Ethernet.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">&#8211; Damaged or faulty ethernet cable\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Damaged or faulty ethernet port<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Incorrect ethernet cable used<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">The charger may connect to Bluetooth, Wi-Fi, or 3G\/4G, but Ethernet is impossible.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Restart the router.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Connect the Ethernet cable to the charger and check the Ethernet port LEDs on the charger (should be flashing green) \u2192 Take a video of the LED behaviour.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. Then unplug the Ethernet cable from the charger and take a clear picture of the connectors on both sides of the cable.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Some Ethernet cables have the cables switched in the two ends. This will work for a computer but not for our chargers.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. The proper connection order is on both ends of the cable, as shown in the picture below.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Check that the same ethernet cable is on another device.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">If not, try with another cable.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; If it still doesn\u2019t work, then it&#8217;s a problem for the internet provider, and the client should contact them.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">5. Do a manual restore and try to connect with the factory settings.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">6. Update back and try to connect.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-4653\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-4653\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #3 - 3G\/4G connection<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-4653\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-4653\"><table><tbody><tr><td><p><span style=\"font-weight: 300;\">Symptom<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">Unable to connect the charger to the 3G\/4G.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">Cause<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">&#8211; Damage to the dongle\u00a0<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Damage to the USB connector<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Inactive sim<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Not fully inserted Dongle<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">The charger might not connect to Bluetooth, Wi-Fi, or ethernet, but the dongle will not connect.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">1. Check the LED on the USB stick.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Blinking blue: Trying to connect to 4G<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Blinking green: Trying to connect to 3G<\/span><\/p><p><span style=\"font-weight: 300;\">2. Sometimes, we don\u2019t know if the dongle is failing because of the charger or because the sim is not correctly configured. To double-check, we can use a Windows OS and connect the dongle to USB (see screenshot explaining the steps below).<\/span><\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-191010\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6.png\" alt=\"Cosmos Troubleshooting Guide B - Image 6\" width=\"1600\" height=\"753\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6.png 1600w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-300x141.png 300w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-1024x482.png 1024w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-768x361.png 768w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-50x24.png 50w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-1536x723.png 1536w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-60x28.png 60w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-6-100x47.png 100w\" sizes=\"(max-width: 1600px) 100vw, 1600px\" \/><\/p><p><span style=\"font-weight: 300;\">3. Check if the sim is correctly positioned on the dongle (see picture below):<\/span><\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-191026 size-medium\" src=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-300x214.png\" alt=\"\" width=\"300\" height=\"214\" srcset=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-300x214.png 300w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-1024x729.png 1024w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-768x547.png 768w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-50x36.png 50w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-1536x1093.png 1536w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-60x43.png 60w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7-100x71.png 100w, https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-7.png 1600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p><p><span style=\"font-weight: 300;\">4. Make sure the sim has data.<\/span><\/p><p><span style=\"font-weight: 300;\">&#8211; Try to insert any user and password if it doesn\u2019t work. Some sims that are supposed only to need the APN but still may not work without a user and password.<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p><\/td><td><p><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p><\/td><\/tr><\/tbody><\/table><p>\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-4654\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-4654\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-caret-right\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-caret-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Root cause #3 - OCPP<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-4654\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-4654\"><table>\n<tbody>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Symptom<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">The charger is unable to connect to the OCPP.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">FW Error code\/name<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">No FW error appears<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">Cause<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">&#8211; Incorrect information entered.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; OCPP server issue.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">&#8211; Software crash.<\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\"><br \/><\/span><span style=\"font-weight: 300;\">Charger is unable to connect to OCPP.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">SOLUTION<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">1. Ask the customer for:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">URL\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">ChargerID<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Password<\/span><\/p>\n<p><span style=\"font-weight: 300;\">2. Make sure this information looks ok (no odd characters, information matches what has been entered.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">3. Check the internet connection and disconnections and if OCPP has been enabled.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">4. Test these credentials with a \u2018lab\u2019 charger (Wallbox staff only), if the charger fails to connect, there is an issue on the OCPP server side.<\/span><\/p>\n<br \/>\n<p><span style=\"font-weight: 300;\">5. Confirm if they have completed a FAT.<\/span><\/p>\n<p><span style=\"font-weight: 300;\">If the charger connects:<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Check the credentials again to ensure they were correctly entered for the customer\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Look for any potential software crashes\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Look for any connectivity issues\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 300;\">Check the logs.<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span style=\"font-weight: 300;\">What if the issue is not solved?\u00a0<\/span><\/p>\n<\/td>\n<td>\n<p><span style=\"font-weight: 300;\">Please <\/span><a href=\"https:\/\/support.wallbox.com\/en\/contact-us\/\"><span style=\"font-weight: 300;\">open a case<\/span><\/a><span style=\"font-weight: 300;\"> through the webform\/Partner Portal.<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><br \/><br \/><br \/><br \/><\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Introduction This guide is designed for installers to identify the issue on-site and implement the solution quickly. For each symptom&#8230;<\/p>\n","protected":false},"author":12,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"ht-kb-category":[5299,11582],"ht-kb-tag":[2805,11583],"class_list":["post-190923","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-troubleshooting-guide","ht_kb_category-cosmos","ht_kb_tag-troubleshooting","ht_kb_tag-cosmos"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center\" \/>\n<meta property=\"og:description\" content=\"Introduction This guide is designed for installers to identify the issue on-site and implement the solution quickly. For each symptom...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/\" \/>\n<meta property=\"og:site_name\" content=\"Wallbox Help Center\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-01T11:07:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-300x255.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"32 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/support.wallbox.com\/en\/#website\",\"url\":\"https:\/\/support.wallbox.com\/en\/\",\"name\":\"Wallbox Help Center\",\"description\":\"Get help for our products &amp; digital solutions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/support.wallbox.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-GB\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#primaryimage\",\"inLanguage\":\"en-GB\",\"url\":\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1.png\",\"contentUrl\":\"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1.png\",\"width\":512,\"height\":436},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#webpage\",\"url\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/\",\"name\":\"Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center\",\"isPartOf\":{\"@id\":\"https:\/\/support.wallbox.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#primaryimage\"},\"datePublished\":\"2025-01-27T14:39:12+00:00\",\"dateModified\":\"2025-04-01T11:07:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/support.wallbox.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Articles\",\"item\":\"https:\/\/support.wallbox.com\/en\/knowledge-base\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Troubleshooting Guide B for Installer Onsite and Charger Offline\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/","og_locale":"en_GB","og_type":"article","og_title":"Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center","og_description":"Introduction This guide is designed for installers to identify the issue on-site and implement the solution quickly. For each symptom...","og_url":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/","og_site_name":"Wallbox Help Center","article_modified_time":"2025-04-01T11:07:36+00:00","og_image":[{"url":"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1-300x255.png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"32 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/support.wallbox.com\/en\/#website","url":"https:\/\/support.wallbox.com\/en\/","name":"Wallbox Help Center","description":"Get help for our products &amp; digital solutions","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.wallbox.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-GB"},{"@type":"ImageObject","@id":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#primaryimage","inLanguage":"en-GB","url":"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1.png","contentUrl":"https:\/\/support.wallbox.com\/wp-content\/uploads\/2025\/01\/Cosmos-Troubleshooting-Guide-B-Image-1.png","width":512,"height":436},{"@type":"WebPage","@id":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#webpage","url":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/","name":"Troubleshooting Guide B for Installer Onsite and Charger Offline - Wallbox Help Center","isPartOf":{"@id":"https:\/\/support.wallbox.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#primaryimage"},"datePublished":"2025-01-27T14:39:12+00:00","dateModified":"2025-04-01T11:07:36+00:00","breadcrumb":{"@id":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/support.wallbox.com\/en\/knowledge-base\/cosmos-troubleshooting-guide-b-end-user-charger-online\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.wallbox.com\/en\/"},{"@type":"ListItem","position":2,"name":"Articles","item":"https:\/\/support.wallbox.com\/en\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"Troubleshooting Guide B for Installer Onsite and Charger Offline"}]}]}},"_links":{"self":[{"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb\/190923","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/comments?post=190923"}],"version-history":[{"count":3,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb\/190923\/revisions"}],"predecessor-version":[{"id":193421,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb\/190923\/revisions\/193421"}],"wp:attachment":[{"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/media?parent=190923"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb-category?post=190923"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/support.wallbox.com\/en\/wp-json\/wp\/v2\/ht-kb-tag?post=190923"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}